The total tower height
= height of entry floor+height of top floor+height of mechanical room+height of stocking deck
= 2,086 + 2,194 + 1,600 + (number of vehicles to be accommodating-2)/2 ¡¿ 1,660
= 5,880 + (number of vehicles to be accommodating-2)/2 ¡¿ 1,660
Example) in case of 40 vehicles, the total tower height = 5,880 + (40-2)/2 ¡¿ 1,660 = 37,420 mm
|
|
|
 |
¡á Standard specification
|
| TYPE |
Front raise type (built-in type, outdoor type) |
Number of vehicles
to be accommodating |
16 ~ 60 vehicles |
| Acceptable automobiles |
5,300L ¡¿2,100W ¡¿ 1,650H, 2,150kg |
| Elevating |
MOTOR |
22 ~ 30 kw |
| SPEED |
50 ~ 100 m/min |
| Horizontal-moving |
MOTOR |
1.5 kw |
| SPEED |
28 m/min |
| Rotation |
MOTOR |
2.2 kw |
| SPEED |
3.5 rpm |
| Operation type |
Computer, Ten keys, Touch screen (optional) |
| Safety device |
Guide light of entry door and inside guide light
Vehicle normal position sensor of the entry door
Fall and overrun prevention system
Emergency stop switch and various safety sensors |
| Power |
220V, 380V, 3©ª, 60Hz |
|
|
 |
|
| |
|
|