Total height of upper tower =
height of entry floor+height of top floor+height of mechanical room+height of upper stocking floor
= 2,086 + 2,194 + 1,600 + (number of vehicles to be accommodating-2)/2 ¡¿ 1,610
= 5,880 + (number of vehicles to be accommodating-2)/2 ¡¿ 1,610
Total height of lower tower =
height of 1 underground floor+floor height of PIT floor+height of lower stocking floor
= 2,100 + 1,100 + (Acceptable number of lower floor-2)/2 ¡¿ 1,610
= 3,200+ (Acceptable number of lower floor-2)/2 ¡¿ 1,610
Example) 34 vehicles on the ground floor, total height in case of 6 vehicles on the underground floor = 9,080 + (34-2)/2 ¡¿ 1,610 + (6-2)/2 ¡¿ 1,610 = 38,060 mm |
|
|
 |
¡á Standard specification
|
| TYPE |
Front raise type (built-in type, outdoor type) |
Number of vehicles
to be accommodating |
16 ~ 60 vehicles |
| Acceptable automobiles |
5,100L ¡¿1,850W ¡¿ 1,600H, 1,850kg |
| Elevating |
MOTOR |
22 ~ 30 kw |
| SPEED |
60 ~ 120 m/min |
| Horizontal-moving |
MOTOR |
1.5 kw |
| SPEED |
28 m/min |
| Rotation |
MOTOR |
2.2 kw |
| SPEED |
3.5 rpm |
| Operation type |
Computer, Ten keys, Touch screen (optional) |
| Safety device |
Guide light of entry door and inside guide light
Vehicle normal position sensor of the entry door
Fall and overrun prevention system
Emergency stop switch and various safety sensors |
| Power |
220V, 380V, 3©ª, 60Hz |
|
|
 |
|
| |
|
|